Exposure of children to aerosol during PE lessons

Main Article Content

Jiří Šafránek
http://orcid.org/0000-0002-4057-9665
Ivana Turčová
http://orcid.org/0000-0001-8591-8125
Martin Braniš
Michal Hájek

Abstract

The greater the physical activity, the greater the amount of air, including pollutants, are inhaled compared to when resting. The school gym environment is in many aspects predisposed to high amounts of aerosol (particulate matter – PM) concentrations, which are cumulated in gyms and re-suspended by exercising pupils during physical education (PE) lessons. PM concentrations (mainly its coarse particles) distinctly rise according to the number of people exercising and the type of activity. The aim of our study was to estimate the aerosol exposure for 32 children exercising with increased ventilation in Prague primary school gyms (18 girls - 10 to 14 years and 14 boys - 10 to 13 years).

The indirect method of transferring heart rate (HR) to minute ventilation (VE) through the exponential regression curve was used to measure pulmonary ventilation. HR was measured by sport-testers during PE lessons. Results of rest and ventilation load values were compared with the values of aerosol weight concentrations, measured continually by a photometer Dust Track and by the Personal Cascade Impactor Sampler.

Results have shown that the average VE multiple during exercising reached 3.8 times in the observed group. The average HR of respondents in the measured exercise unit was 150.6 beats·min-1 and the estimated x̄ VE 24.4 litres·min-1. VE multiple values of individual pupils in an exercise unit correlate significantly (r = 0.78) with average HR values in the time unit. Aerosol concentrations reached in measured PE lessons from PM2.5 22.4 to 24.4 [μg·m-3] and from PM10 60.14 to 101.12 [μg·m-3]. If the tested pupils raised their ventilation to the estimated 3.8 times their resting value, exposure to PM would exceed the sanitary limits set by WHO guidelines for school environments. Out of 112 observed days, in three Prague primary schools, 89% of days in school gyms and 46% of days outdoors were over the limit (under the above stated conditions of VE multiple).

The study results indicate that during increased physical load inhalation exposure exceeds pollutant limit concentrations. We recommend that indoor areas, in which pupils exercise, should be cleaned with more care than places in which pupils stay in rest.

Metrics

Metrics Loading ...

Article Details

How to Cite
Šafránek, J., Turčová, I., Braniš, M., & Hájek, M. (2017). Exposure of children to aerosol during PE lessons. Envigogika, 12(2). https://doi.org/10.14712/18023061.554
Section
Reviewed Papers
Author Biographies

Jiří Šafránek, Charles University, Faculty of Sports

Univerzita Karlova v Praze, Fakulta tělesné výchovy a sportu, Katedra sportů v přírodě, José Martího 31, 162 52 Praha 6

Ivana Turčová, Charles University, Faculty of Sports

Univerzita Karlova v Praze, Fakulta tělesné výchovy a sportu, Katedra sportů v přírodě, José Martího 31, 162 52 Praha 6

Martin Braniš, Faculty of Science, Charles University

Faculty of Science, Charles University

Michal Hájek, Charles University, Faculty of Sports

Univerzita Karlova v Praze, Fakulta tělesné výchovy a sportu, Katedra sportů v přírodě, José Martího 31, 162 52 Praha 6

References

Atkinson, G. (1997). Air pollution and exercise. Sports Exercise and Injury, 3(1), 2-8.

Braniš, M., Šafránek, J., & Hytychová, A. (2009). Exposure of children to airborne particulate matter of different size fractions during indoor physical education at school. Building and Environment, 44(6), 1246-1252.

Braniš, M., Šafránek, J., & Hytychová, A. (2011). Indoor and outdoor sources of size-resolved mass concentration of particulate matter in a school gym - implications for exposure of exercising children. Environmental Science and Pollution Research, 18(4), 598-609.

Braniš, M., & Šafránek, J. (2011). Characterization of coarse particulate matter in school gyms. Environmental Research, 111(4), 485-491.

Brunekreef, B., & Forsberg, B. (2005). Epidemiological evidence of effects of coarse airborne particles on health. Eur. Respir. J., 26, 309–318.

Carlisle, A., & Sharp, N. (2001). Exercise and outdoor ambient air pollution. British Journal of Sports Medicine, 35, 214-222.

Daigle, C. C., Chalupa, D. C., Gibb, F. R., Morrow, P. E., Oberdorster, G., Uttel, M. J., & Frampton, M. W. (2003). Ultrafine particle deposition in humans during rest and exercise. Inhalation Toxicology, 15, 539-552.

DeKok, T. M. C. M., Driece H. A. L, Hogervorst J. G. F., & Briede J. J. (2006). Toxicological assessment of ambient and traffic-related particulate matter: A review of recent studies. Mutat Res, 613, 103–122.

Diapouli, E., Chaloulakou, A., & Spyrellis, N. (2007). Indoor and outdoor particulate matter concentrations at schools in the Athens area. Indoor and Built Environment, 16, 55-61.

Ekmekcioglu, D., & Keskin, S. S. (2007). Characterization of indoor air particulate matter in selected elementary schools in Istanbul Turkey. Indoor and Built Environment, 16(2), 169-176.

Fairclough, S., & Stratton, G. (2005). ‘Physical education makes you fit and healthy’. Physical education's contribution to young peopleʼs physical activity levels. Health Educational Research, 20(1), 14-23.

Fox, A., Harley, W., Feigley, C., Salzberg, D., Toole, C., Sebastian, A. et al. (2005). Large particles are responsible for elevated bacterial marker levels in school air upon occupation. J. Environ. Monit., 7, 450–456.

Fromme, H., Twardella, D., Dietrich, S., Heitmann, D., Schierl, R., Liebl, B., & Rüden, H. (2007). Particulate matter in the indoor air of classrooms - exploratory results from Munich and surrounding area. Atmospheric Environment, 41(4), 854–866.

Habil, M., & Taneja, A. (2011). Children’s exposure to indoor particulate matter in naturally ventilated schools in India. Indoor and Built Environment, 20(4), 430-448.

Iskandar, A., Jovanovic Andersen, Z., Bønnelykke, K., Ellermann, T., Kaae Andersen, K., & Bisgaard, H. (2012). Coarse and fine particles but not ultrafine particles in urban air trigger hospital admission for asthma in children. Thorax, 67, 252-257.

Kotlík, B., Kazmanová, H., Kratěnová, J., & Holcátová, I. (2001). Monitoring the indoor environment in the Czech Republic. Indoor and Built Environment, 10(3-4), 154-159.

Lee, S. C., & Chang, M. (2000). Indoor and outdoor air quality investigation at schools in Hong Kong, Chemosphere, 41, 109-113.

Mejía, J. F., Low Choy, S., Mengersen, K., & Morawska, L. (2011). Methodology for assessing exposure and impacts of air pollutants in school children: Data collection, analysis and health effects - A literature review. Atmospheric Environment, 45(4), 813-823.

Mermier, C. M., Samet, J. M., Lambert, W. E., & Chick, T. W. (1993). Assessment of heart rate as a predictor of ventilation. Research Report Health Effect Institute, (59), 19-55.

Misra, Ch., Singh, M., Shen, S., Sioutas, C., & Hall, P. (2002). Development and evaluation of a personal cascade impactor sampler. Journal of Aerosol Science, 33, 1027-1047.

Pope, C. A. III., Burnett, R. T., Thun, M. J., Calle, E. E., Krewski, D., Ito, K., & Thurston, G. D. (2002). Lung cancer, cardiopulmonary mortality, and long-term exposure to fine particulate air pollution. JAMA, 287, 1132-1141.

Pope, C. A. III., Rodermund, D. L., & Gee, M. M. (2007). Mortality effects of a copper smelter strike and reduced ambient sulphate particulate matter air pollution. Environmental Health Perspectives, 115, 679-683.

Pope, C. A. III, Ezzati, M., & Dockery, D. W. (2009). Fine-particulate air pollution and life expectancy in the United States. New England Journal Medicine, 360, 376-386.

Silverman, S., & Kulinna, P. H. (1999). What Are Children’s Heart-Rates during British Physical Education Lessons? The Journal of Physical Education, Recreation & Dance, 70(2), 8.

Stratton, G. (1996). Children’s heart rates during British physical education lessons. Journal of Teaching in Physical Education Paediatric Exercise Science, 8(3), 215-233.

Vaclavik-Bräuner, E., Forchhammer, L., Møller, P., Simonsen, J., Glasius, M.,Wahlin, P. et al. (2007). Exposure to ultrafine particles from ambient air and oxidative stress-induced cDNA damage. Environ Health Perspect, 115(8), 1171–82.

Wallis, L. A., Healy, M., Undy, M. B., & Maconochie, I. (2005). Age related reference ranges for respiration rate and heart rate from 4 to 16 years. Archives of Disease in Childhood, 90, 1117-1121.

Wang, G. Y., Pereira, B., & Mota, J. (2005). Indoor physical education measured by heart rate monitor. A case study in Portugal. Journal of Sports Medicine and Physical Fitness, 45(2), 171-177.

WHO (2006). World Health Organization. Air quality guidelines for particulate matter, ozone, nitrogen dioxide and sulphur dioxide. Global update 2005. Summary of risk assessment [online]. c2006, [2012-02-28]. Available from: http://whqlibdoc.who.int/hq/2006/WHO_SDE_PHE_OEH_06.02_eng.pdf

Zuurbier, M., Hoek, G., Hazell, P., & Brunekreef, B. (2009). Minute ventilation of cyclists, car and bus passengers: an experimental study. Environmental Health, 8, 48.